{"id":3315,"date":"2017-01-24T17:32:07","date_gmt":"2017-01-24T14:32:07","guid":{"rendered":"http:\/\/lotgroup.eu\/?page_id=3315"},"modified":"2017-06-14T15:34:37","modified_gmt":"2017-06-14T12:34:37","slug":"proray-scada-centralized-traffic-control-system","status":"publish","type":"page","link":"https:\/\/lotgroup.eu\/bg\/product\/rail-transport\/proray-scada-centralized-traffic-control-system\/","title":{"rendered":"Proray SCADA Centralized Traffic Control System"},"content":{"rendered":"<section class=\"wpb-content-wrapper\">[vc_row][vc_column][vc_single_image image=&#8220;3316&#8243; css_animation=&#8220;bottom-to-top&#8220;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<strong>PRORAY SCADA<\/strong> centralized traffic control system is a software package intended to collect, process, display and archive information about train traffic and its control.<\/p>\n<p>Software package is operated under QNX real time operating system intended for embedded systems. QNX operating system is transferred to many platforms and can be operated on any modern processor that is used with embedded systems.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column]<style>.vcex-heading.vcex_69ea0afeebd43 .vcex-heading-inner{border-color:#1e73be;}.vcex-heading.vcex_69ea0afeebd43{border-color:#1e73be;}<\/style><h2 class=\"vcex-heading vcex-heading-bottom-border-w-color vcex-module wpex-text-2xl wpex-font-normal  wpb_animate_when_almost_visible wpb_left-to-right left-to-right wpex-border-b-2 wpex-border-solid wpex-border-main vcex_69ea0afeebd43\"><span class=\"vcex-heading-inner wpex-inline-block wpex-relative wpex-pb-5 wpex-border-b-2 wpex-border-solid wpex-border-accent\">Proray SCADA provides:<\/span><\/h2>[\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]\n<ul>\n<li><strong>collection and analyze of data<\/strong> received from system trackside assets (points, traffic lights, point sensors, etc.);<\/li>\n<li>signal <strong>state visualization<\/strong>;<\/li>\n<li><strong>keeping history and archiving<\/strong> of system states, signals and emergency situations;<\/li>\n<li><strong>system objects centralized control<\/strong> from operator\u2019s automated work place;<\/li>\n<li><strong>reliable and safe data transfer<\/strong> to the operations control center;<\/li>\n<li><strong>access right differentiation and access authorization<\/strong> to the data sources and control<br \/>\nfacilities.<\/li>\n<\/ul>\n[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column]<style>.vcex-heading.vcex_69ea0afeed3d8 .vcex-heading-inner{border-color:#1e73be;}.vcex-heading.vcex_69ea0afeed3d8{border-color:#1e73be;}<\/style><h2 class=\"vcex-heading vcex-heading-bottom-border-w-color vcex-module wpex-text-2xl wpex-font-normal  wpb_animate_when_almost_visible wpb_left-to-right left-to-right wpex-border-b-2 wpex-border-solid wpex-border-main vcex_69ea0afeed3d8\"><span class=\"vcex-heading-inner wpex-inline-block wpex-relative wpex-pb-5 wpex-border-b-2 wpex-border-solid wpex-border-accent\">System Composition<\/span><\/h2>[\/vc_column][\/vc_row][vc_row][vc_column]<style>.vcex-heading.vcex_69ea0afeedfc5 .vcex-heading-inner{border-color:#cccccc;}.vcex-heading.vcex_69ea0afeedfc5{border-color:#cccccc;font-size:18px;}<\/style><h3 class=\"vcex-heading vcex-heading-bottom-border-w-color vcex-module wpex-text-2xl wpex-font-normal  wpb_animate_when_almost_visible wpb_right-to-left right-to-left wpex-border-b-2 wpex-border-solid wpex-border-main vcex_69ea0afeedfc5\"><span class=\"vcex-heading-inner wpex-inline-block wpex-relative wpex-pb-5 wpex-border-b-2 wpex-border-solid wpex-border-accent\">Station Level<\/span><\/h3>[\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]Station level includes operator\u2019s automated work places (AWP) and set of station servers intended to receive, process and store the information from trackside assets. Station level includes operator\u2019s automated work places (AWP) and set of station servers intended to receive, process and store the information from trackside assets.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column]<style>.vcex-heading.vcex_69ea0afeeeb71 .vcex-heading-inner{border-color:#cccccc;}.vcex-heading.vcex_69ea0afeeeb71{border-color:#cccccc;font-size:18px;}<\/style><h3 class=\"vcex-heading vcex-heading-bottom-border-w-color vcex-module wpex-text-2xl wpex-font-normal  wpb_animate_when_almost_visible wpb_right-to-left right-to-left wpex-border-b-2 wpex-border-solid wpex-border-main vcex_69ea0afeeeb71\"><span class=\"vcex-heading-inner wpex-inline-block wpex-relative wpex-pb-5 wpex-border-b-2 wpex-border-solid wpex-border-accent\">Operations Control Center Level<\/span><\/h3>[\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]Operations control center level comprises operator\u2019s AWPs as well as system configurator\u2019s AWP, communication equipment with station level, video wall and data base server intended to collect and store configuration of system elements as well as system state history.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-3332\" src=\"https:\/\/lotgroup.eu\/wp-content\/uploads\/2017\/01\/Operations_Control_Center_Level_Cheme_en.jpg\" alt=\"Operations Control Center Level\" width=\"1201\" height=\"1203\" srcset=\"https:\/\/lotgroup.eu\/wp-content\/uploads\/2017\/01\/Operations_Control_Center_Level_Cheme_en.jpg 1201w, https:\/\/lotgroup.eu\/wp-content\/uploads\/2017\/01\/Operations_Control_Center_Level_Cheme_en-300x300.jpg 300w, https:\/\/lotgroup.eu\/wp-content\/uploads\/2017\/01\/Operations_Control_Center_Level_Cheme_en-600x601.jpg 600w, https:\/\/lotgroup.eu\/wp-content\/uploads\/2017\/01\/Operations_Control_Center_Level_Cheme_en-768x769.jpg 768w, https:\/\/lotgroup.eu\/wp-content\/uploads\/2017\/01\/Operations_Control_Center_Level_Cheme_en-1200x1202.jpg 1200w\" sizes=\"(max-width: 1201px) 100vw, 1201px\" \/>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column]<style>.vcex-heading.vcex_69ea0afeef747 .vcex-heading-inner{border-color:#1e73be;}.vcex-heading.vcex_69ea0afeef747{border-color:#1e73be;}<\/style><h2 class=\"vcex-heading vcex-heading-bottom-border-w-color vcex-module wpex-text-2xl wpex-font-normal  wpb_animate_when_almost_visible wpb_left-to-right left-to-right wpex-border-b-2 wpex-border-solid wpex-border-main vcex_69ea0afeef747\"><span class=\"vcex-heading-inner wpex-inline-block wpex-relative wpex-pb-5 wpex-border-b-2 wpex-border-solid wpex-border-accent\">System Components Structure<\/span><\/h2>[\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<strong>ProRay SCADA<\/strong> system includes such components <strong>as client, data base server, node server and devices<\/strong>.<\/p>\n<p><strong>Client<\/strong> is a part of the system that provides interaction with users and comprises video wall, which displays general information about the state of all system elements as well as operator\u2019s AWP, which displays information about certain system components and controls them.<\/p>\n<p><strong>Data base server<\/strong> is a part of the system that ensures storage and provides information about sequence of states and settings. It includes configuration data base of the system elements, data base of the system elements history as well as history collection client i.e. current state of the system elements.<\/p>\n<p><strong>Node server<\/strong> includes data base server and logic server, history collection module, Modbus RTU device driver, Modbus TCP device driver and Custom additional device driver.<\/p>\n<p>System <strong>devices<\/strong> include Modbus RTU device, Modbus TCP device, Custom additional device.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-3333\" src=\"https:\/\/lotgroup.eu\/wp-content\/uploads\/2017\/01\/System_Components_Structure_PRO-SCADA_eng.jpg\" alt=\"System Components Structure PRO-SCADA\" width=\"1200\" height=\"1145\" srcset=\"https:\/\/lotgroup.eu\/wp-content\/uploads\/2017\/01\/System_Components_Structure_PRO-SCADA_eng.jpg 1200w, https:\/\/lotgroup.eu\/wp-content\/uploads\/2017\/01\/System_Components_Structure_PRO-SCADA_eng-600x573.jpg 600w, https:\/\/lotgroup.eu\/wp-content\/uploads\/2017\/01\/System_Components_Structure_PRO-SCADA_eng-768x733.jpg 768w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<strong>To realize interaction between the users and the hardware the system includes the following components:<\/strong><\/p>\n<ul>\n<li><strong>users<\/strong> who follow up complex changes in hardware device states and if necessary control them;<\/li>\n<li><strong>terminal<\/strong> that provides user friendly interface of interaction between users and hardware devices.<\/li>\n<\/ul>\n<p><strong>Terminals include the following software components:<\/strong><\/p>\n<ul>\n<li><strong>state display module<\/strong> that shows the users current state of hardware and logic elements of the system;<\/li>\n<li><strong>state history display module<\/strong> shows the users history of state changes of the system hardware and logic elements;<\/li>\n<li><strong>state control module<\/strong> allows the users to set (change) the state of system hardware elements;<\/li>\n<li><strong>authentication module<\/strong> is a system of verification and differentiation of user\u2019s access rights to different system control functions.<\/li>\n<\/ul>\n<p><strong>Servers are intended to receive, process and accumulate the information from hardware devices and terminals. <\/strong><strong>Servers perform the following functions:<\/strong><\/p>\n<ul>\n<li><strong>Data analyze and collection.<\/strong> Servers process and accumulate data from hardware and logic components of the system.<\/li>\n<li><strong>Control of the system hardware devices.<\/strong> Servers collect, process and transmit the commands to the hardware components of the system.<\/li>\n<li><strong>Configuration of the system components.<\/strong> Servers process and store setting changes of hardware and logic components of the system.<\/li>\n<li><strong>Accumulation and processing of change history.<\/strong> Servers collect and process state history of logic and hardware components of the system.<\/li>\n<\/ul>\n[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column]<style>.vcex-heading.vcex_69ea0afef02c1 .vcex-heading-inner{border-color:#1e73be;}.vcex-heading.vcex_69ea0afef02c1{border-color:#1e73be;}<\/style><h2 class=\"vcex-heading vcex-heading-bottom-border-w-color vcex-module wpex-text-2xl wpex-font-normal  wpb_animate_when_almost_visible wpb_left-to-right left-to-right wpex-border-b-2 wpex-border-solid wpex-border-main vcex_69ea0afef02c1\"><span class=\"vcex-heading-inner wpex-inline-block wpex-relative wpex-pb-5 wpex-border-b-2 wpex-border-solid wpex-border-accent\">Advantages of Proray SCADA System Implementation<\/span><\/h2>[\/vc_column][\/vc_row][vc_row][vc_column width=&#8220;1\/4&#8243;][vc_row_inner][vc_column_inner width=&#8220;1\/4&#8243;][vc_column_text]\n<h4><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-3348\" src=\"https:\/\/lotgroup.eu\/wp-content\/uploads\/2017\/01\/High_information_capacity_and_reliability-1.jpg\" alt=\"High Information Capacity and Reliability\" width=\"200\" height=\"200\" \/><\/h4>\n[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8220;3\/4&#8243;][vc_column_text]\n<h4>High Information Capacity and Reliability<\/h4>\n[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_column_text css_animation=&#8220;top-to-bottom&#8220;]System implementation allows to analyze large amounts of information about system device status suitable for archiving.[\/vc_column_text][\/vc_column][vc_column width=&#8220;1\/4&#8243;][vc_row_inner][vc_column_inner width=&#8220;1\/4&#8243;][vc_column_text]\n<h4><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-3347\" src=\"https:\/\/lotgroup.eu\/wp-content\/uploads\/2017\/01\/Analyze_of_Operators_Actions-1.jpg\" alt=\"Analyze of Operator\u2019s Actions\" width=\"200\" height=\"200\" \/><\/h4>\n[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8220;3\/4&#8243;][vc_column_text]\n<h4>Analyze of Operator\u2019s Actions<\/h4>\n[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_column_text css_animation=&#8220;bottom-to-top&#8220;]Keeping the history of the system device status allows to analyze operator\u2019s actions, define mistakes and correct them.[\/vc_column_text][\/vc_column][vc_column width=&#8220;1\/4&#8243;][vc_row_inner][vc_column_inner width=&#8220;1\/4&#8243;][vc_column_text]\n<h4><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-3349\" src=\"https:\/\/lotgroup.eu\/wp-content\/uploads\/2017\/01\/Improving_the_quality_of_operators_work-1.jpg\" alt=\"Improving the Quality of Operator\u2019s Work\" width=\"200\" height=\"200\" \/><\/h4>\n[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8220;3\/4&#8243;][vc_column_text]\n<h4>Improving the Quality of Operator\u2019s Work<\/h4>\n[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_column_text css_animation=&#8220;top-to-bottom&#8220;]User friendly interface of the system allows to decrease the level of tiredness and increase accuracy of operator\u2019s work.[\/vc_column_text][\/vc_column][vc_column width=&#8220;1\/4&#8243;][vc_row_inner][vc_column_inner width=&#8220;1\/4&#8243;][vc_column_text]\n<h4><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-3346\" src=\"https:\/\/lotgroup.eu\/wp-content\/uploads\/2017\/01\/Adaptability-1.jpg\" alt=\"Adaptability\" width=\"200\" height=\"200\" \/><\/h4>\n[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8220;3\/4&#8243;][vc_column_text]\n<h4>Adaptability<\/h4>\n[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_column_text css_animation=&#8220;bottom-to-top&#8220;]This system is open and extensible. It can be connected to any types of electric interlocking system. The system is easy to adapt at the design stage as well as at its modernization stage during the operation.[\/vc_column_text][\/vc_column][\/vc_row]\n<\/section>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_single_image image=&#8220;3316&#8243; css_animation=&#8220;bottom-to-top&#8220;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]PRORAY SCADA centralized traffic control system is a software package intended to collect, process, display and archive information about train traffic and its control. Software package is operated under QNX real time operating system intended for embedded systems. QNX operating system is transferred to many platforms and can be operated on any modern&hellip;<\/p>\n","protected":false},"author":6,"featured_media":0,"parent":448,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"translation":{"provider":"WPGlobus","version":"2.12.2","language":"bg","enabled_languages":["en","ru","bg","vi"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"ru":{"title":true,"content":true,"excerpt":false},"bg":{"title":false,"content":false,"excerpt":false},"vi":{"title":true,"content":true,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/lotgroup.eu\/bg\/wp-json\/wp\/v2\/pages\/3315"}],"collection":[{"href":"https:\/\/lotgroup.eu\/bg\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/lotgroup.eu\/bg\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/lotgroup.eu\/bg\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/lotgroup.eu\/bg\/wp-json\/wp\/v2\/comments?post=3315"}],"version-history":[{"count":48,"href":"https:\/\/lotgroup.eu\/bg\/wp-json\/wp\/v2\/pages\/3315\/revisions"}],"predecessor-version":[{"id":4392,"href":"https:\/\/lotgroup.eu\/bg\/wp-json\/wp\/v2\/pages\/3315\/revisions\/4392"}],"up":[{"embeddable":true,"href":"https:\/\/lotgroup.eu\/bg\/wp-json\/wp\/v2\/pages\/448"}],"wp:attachment":[{"href":"https:\/\/lotgroup.eu\/bg\/wp-json\/wp\/v2\/media?parent=3315"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}